Insulation Roll, Batt & Thermal Calculator
Calculate thermal insulation rolls, batts, and required R-value for walls and attics. Optimize home energy efficiency and heating costs.
Construction CalculatorsPerfect match! Minimal waste.
Hardware Store BOM
- Net Area15.0 m²
- Primary Insulation (10cm)5 Packs
- Recommended Vapor Barrier Tape1 Rolls
Poor insulation
How to Use the Insulation Roll, Batt & Thermal Calculator
Step-by-step guide to estimating mineral wool, fiberglass, EPS/XPS packs, framing cavity fits, and thermal R-value
Select Material & Product Format
Choose between Rockwool mineral wool, Fiberglass glass wool, or EPS/XPS rigid foam boards, and select your product packaging format: Continuous Rolls (for lofts) or Semi-rigid Batts / Slabs (for stud walls).
Enter Wall or Roof Dimensions
Input wall or ceiling length and height/width in meters (or feet). Toggle between Metric (cm, m²) and Imperial (in, sq ft) depending on your product specifications.
Verify Framing Spacing & Cavity Matcher
Enter your framing stud/rafter on-center spacing (e.g. 60 cm or 16"/24") and insulation roll/batt width. The matcher alerts you if excess trimming or gaps will occur.
Configure Primary Layer & Pack Coverage
Set the primary insulation thickness (e.g. 10 cm or 15 cm) and the coverage per pack (m² or sq ft) stated on the manufacturer label.
Add Double Layer (Cross-Battening) & Cutouts
Check "Double Layer" to add a secondary perpendicular layer (e.g. 5 cm) to eliminate thermal bridging across wooden rafters/studs. Add window and door cutouts to deduct negative space.
Review BOM & Estimated Thermal R-Value
Inspect required packs or rolls, rolls of vapor barrier sealing tape, estimated thermal R-value, and building code compliance. Click "Copy Material List" to save your purchase order.
Frequently Asked Questions (FAQ)
Expert building science advice on fiberglass vs. rockwool, friction-fit sizing, thermal bridging, and vapor barriers
Q:What is the key difference between fiberglass (glass wool) and rockwool (mineral wool)?
Both are fibrous mineral insulations, but rockwool is spun from volcanic basalt rock, making it denser, non-combustible up to 1,000°C (Class A1 fire rating), moisture-repellent, and superior for acoustic sound absorption. Fiberglass is spun from recycled molten glass; it is lighter, highly compressible for easy transport in rolls, and cost-effective, though it requires strict vapor barrier protection against moisture.
Q:Why should insulation be cut slightly wider than the stud cavity?
Insulation batts should always be cut 10 to 15 mm (approx. 1/2 inch) wider than the clear distance between wooden studs or rafters. This allows the springy fibrous batt to achieve a snug "friction-fit" against the framing without slumping or sagging over time, preventing cold air convection bypass gaps. However, never forcefully crush or compress the insulation thickness, as compressed air pockets drastically reduce rated R-value.
Q:Why is double-layer cross-battening recommended for roofs and exterior walls?
Solid timber studs and rafters act as "thermal bridges"—wood conducts heat 3 to 4 times faster than mineral insulation. Installing a primary layer between structural rafters and a second perpendicular layer over counter-battens covers the wood framing entirely. This breaks thermal bridging, prevents ghosting stripes on drywall, reduces condensation risk, and dramatically raises the total assembly R-value.
Q:What is the difference between R-value and U-value?
R-value measures thermal resistance (how well a material resists conductive heat transfer); higher R-value means superior insulation performance. U-value measures thermal transmittance (the rate of heat loss through a building envelope assembly per unit area per degree of temperature difference); lower U-value means better thermal efficiency (U = 1 / R_total).
Q:Which side of the insulation should the vapor barrier face?
In heating-dominated climates (cold and temperate zones), the vapor control layer (retarder/barrier) must always be installed on the warm, conditioned interior side of the home (between the insulation and the plasterboard). This prevents warm indoor air moisture from migrating into the cold cavity and condensing into hidden mold and structural wood rot. All laps and staples must be sealed with specialized acrylic vapor tape.
Q:What minimum R-value should I aim for modern building energy codes?
In modern building standards, pitched roofs and cold lofts require an R-value of at least R-38 to R-49 (metric RSI 6.7 to 8.6 m²K/W, equivalent to 24–35 cm of high-grade mineral wool). Exterior above-grade walls generally require R-15 to R-24 (metric RSI 2.6 to 4.2 m²K/W, equivalent to 10–16 cm of insulation).
Variables:
- A_net: Net Area (Total Area - Cutouts)
- C: Coverage per Pack
- w_%: Wastage factor (5% or 15%)
- T: Insulation Thickness (m)
- \lambda: Thermal Conductivity (W/mK)
- ⌈ x ⌉: Round up to the nearest whole integer